- Description
- Inquiry
TB-231024-V-203 Electrical Transformer Trainer
Technical Features:
- This trainer should be designed to meet the operational training of electrical transformer, covering a variety of training topics for single phase and three phase characteristics, as well as parametric measurement
- The frame should adopt standard aluminum profile with modular experiment panel design, thus, making it easy to build different experiment combination on the flexible two-layer structure
- All the upper parts should be removable including the experiment module, power supply module and frame support
- All terminals should be led out on printed composite panel with 4mm safety socket and connected by full sealing sheathed pluggable connector
- The complete unit should be movable with lockable truckles on bottom
Training Contents:
- Single Phase Transformer:
- Measurement of the single phase transformer ratio and parameter by no-load and short circuit experiment
- Drawing out of the T type equivalent circuit diagram according to parameters to be measured from no-load and short circuit experiment
- Measurement of the running characteristic of transformer by resistive / inductive / capacitive load experiment
- Parallel operation of transformer (polarity discrimination, parallel two transformers)
- Three Phase Transformer:
- High / Low voltage winding discrimination, primary / secondary polarity measurement
- Measurement of the three phase transformer ratio and parameter by no-load and short circuit experiment
- Three phase transformer Y-Y12 connection
- Three phase transformer Y-Y6 connection
- Three phase transformer Y-∆11 connection
- Three phase transformer Y-∆5 connection
- Voltage vector diagram of three phase transformer under different connections
Technical Parameters:
- Mobile aluminium experiment stand:
- High compressed chipboard tabletop & baseplate
- Solid impact-resistant protective edging
- Minimum 6 extruded aluminium profiles with 8 or higher grooves
- 3 to 4 H-shaped profiles for panel organization
- Minimum 4 swivelling casters, at least 2 should have brakes
- Table & upper frame part should be separable for easy delivery
- Cable holder must be attached to side column for at least 48 cable pcs
- Three phase power supply:
- RCCB and momentary pushbutton with lamp, green / red
- Key switch, 1NO/NC and AC contactor
- Input CEE socket, output 4mm safety socket
- Three phase voltage regulator:
- Minimum 1KW regulator, 0 ~ 450V, 0 ~ 250V variable output
- Indicating lamp R/G/Y
- Output voltage monitoring meter x3 or higher
- Selective input and output voltage display
- Single phase transformer 1.0:
- PN = 77W, UN = 220V/55V, IN = 0.35A/1.4A
- Transformer x3
- With all terminals led to colorized 4mm safety socket
- Three phase transformer 1.0:
- PN = 200W, UN = 220V/55V, IN = 0.52A/2.09A
- With all terminal led to colorized 4mm safety socket
- Power & Power factor meter 1.0:
- Single phase active power meter, digital, 0 ~ 1000W x2
- Power factor meter, digital, 380V/5A
- With all terminal led to colorized 4mm safety socket
- AC voltmeter & AC ammeter 2.0:
- Voltmeter digital AC 0 ~ 450V x3
- Ammeter digital AC 0 ~ 3A x3
- With all terminal led to colorized 4mm safety socket
- Standard size available for frame insertion
- Capacitive load 1.0:
- Fuse protector 3A x 3
- 3-fold capacitors of 1uF/2uF/4uF/6uF
- With all terminal led to colorized 4mm safety socket
- Inductive load 1.0:
- Autoformer regulator 0 ~ 250V with fixed inductor group x3
- Inductance value 1H, adjustable, 0.48A
- Fuse protectors x3
- With all terminal led to colorized 4mm safety socket
- Resistive load 1.0:
- Double-linked resistor x3
- Each with variable range 0 ~ 900Ω, 0.41A
- Fuse protector x6
- Accessories:
- Safety whole sealing cable: conductor cross section: 16AWG tinned copper wire, 3kV, 20A, with axial socket
- Experiment guidebook
- Wiring instruction map