SS19801 Adsorption Trainer Vocational Training Equipment Fluids Engineering Experiment Equipment

SS19801 Adsorption Trainer Vocational Training Equipment Fluids Engineering Experiment Equipment

SS19801 Adsorption Trainer Vocational Training Equipment Fluids Engineering Experiment Equipment for college, vocational training center, university. 

  • Description
  • Inquiry

SS19801 Adsorption Trainer Vocational Training Equipment Fluids Engineering Experiment Equipment

1.Description

Adsorption demonstrates the removal of dissolved substances by adsorption. During adsorption the substances dissolved in the raw water are called adsorbate.

A pump transports the water from a tank in a circuit with two adsorbers filled with activated carbon. The pump transports treated water to the first adsorber. A concentrated adsorbate solution is added to the treated water flow using a metering pump. The raw water produced in this way enters the adsorber and flows through the activated carbon fixed bed. Here the adsorbate adsorbs on the activated carbon. To remove any quantities of adsorbate still present from the water, the water then flows through a second adsorber (safety adsorber). The treated water is returned to the feed line of the first adsorber where concentrated adsorbate solution is added once again. This creates a closed water circuit.

The flow rates of both pumps can be adjusted. Thereby the following parameters can be varied:

– concentration of the adsorbate in the raw water

– contact time of the raw water with the activated carbon

The water temperature can be controlled. This allows for the temperature effect of the adsorption to be investigated. Flow rate, temperature and pressure are continuously measured. Sampling points are arranged in such a way that breakthrough curves and concentration profiles can be plotted.

Analysis technology is required to evaluate the experiments. The choice of analysis technology depends on the adsorbate used. Methylene blue can e.g. be used as adsorbate. The concentration of methylene blue can be determined using a photometer.

2. Specifications
Two adsorbers with activated carbon filling
adsorber with 8 sampling points
safety adsorber for closed water circuit
continuous process
metering pump for concentrated adsorbate solution
pump for recirculating the treated water
water temperature control
digital temperature indication
flow rate adjustable
change of adsorbate concentration and contact time

3.Technical data

Adsorber and safety adsorber

-inner diameter: each 60mm

-height: each 600mm

-capacity: each 1700cm3

Tanks

-treated water: 45L

-adsorbate solution: 45L

Circulation pump

-max. flow rate: 180L/h

-max. head: 10m

Metering pump

-max. flow rate: 2.1L/h

-max. head: 160m

Heater

-max. power: 500W

Measuring ranges

-flow rate: 0-60L/h

-temperature: 0-60°C

-pressure: 0-2.5bar

-230V, 50Hz, 1 phase

-230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase

Dimensions and weight

-LxWxH: 1500x790x1900mm

-Weight: approx. 180kg

Accessories

-1 packing unit of activated carbon

-1 set of test tubes

-1 set of tools

-1 set of instructional material

We will contact you within 1 working day, please pay attention to the email.