– familiarisation with a heating circuit
– familiarisation with temperature control
* two-point controller
* PID controller
* recording of step response
– recording of fitting and pump characteristics
– energy balances
– determining pump efficiency from hydraulic power and electrical power consumption
– heat transfer with convector (water-to-air heat exchanger with fan)
– comparison of circulating pumps
* conventional pump
* differential pressure controlled pump
Specification
[1] fundamentals of energy efficient heating technology
[2] closed water circuit with 2 circulating pumps, expansion vessel, heater and convector
[3] 2-point and PID software controller for temperature: reference variable, hysteresis and PID parameters adjustable
[4] boiler safety group according
[5] 7 differential pressure sensors, 4 temperature sensors, 1 effective power sensor and 1 flow rate sensor
[6] software with control functions and data acquisition via USB under Windows Vista or
Windows 7
Technical Data
Conventional circulating pump, 3 stages
– power consumption: 43…80W
– max. flow rate: 3,7m³/h
– max. head: 6,2m
Differential pressure-controlled circulating pump
– power consumption: 4…50W
– max. flow rate: 3,5m³/h
– max. head: 6m
Electric heater: 2.000W
Expansion vessel: 2L
Software controller
– adjustable reference variable: 0…80°C
Measuring ranges
– differential pressure: 5x 0…600mbar, 2x 0…100mbar
– temperature: 0…100°C
– flow rate: 1…50L/min
– effective power: 0…200W
Dimensions and Weight
LxWxH: 2.000x750x1.760mm
Weight: approx. 150kg
Required for Operation
230V, 50Hz, 1 phase
Related Products
Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
SR3002 Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
Brand: ShouldShine
Model:SR3002
Learning Objectives / Experiments
– thermal expansion of different materials such as PVC, PE, copper and steel
– determination of thermal expansion coefficients and the expansion force
– measurement of pipe elongation
– effect of varying pipe diameter
– expansion compensator
Specification
[1] investigating the thermal expansion of different pipe sections
[2] pipe sections can be selected by ball valves
[3] water connections made using quick-release couplings
[4] operation with hot and cold water supplies
[5] adjustment of the water temperature using mixing battery with thermocouple
[6] temperature measurement using battery-operated digital thermometer
[7] force measuring device to determine the expansion force
Technical Data
Pipe section length: 1000mm
Nominal diameters- PVC, PE, Cu: – Cu: – Steel: 1/2″
Mixing battery connection: 1/2″
Force measuring device
– spring rate per spring: 78N/mm
– total spring rate c: 156N/mm
Measuring range
– temperature: -50…90°C
Dimensions and Weight
LxWxH: 1650x700x1850mm
Weight: approx. 100kg
Required for Operation
Cold and hot water connectionCentral Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BExpansion vessel training panel Vocational Training Equipment
SR3007 Expansion vessel training panel Vocational Training Equipment Teaching Equipment for college, university.
Installation technology: losses in a pipe system Educational Equipment
SR3005 Installation technology: losses in a pipe system Technical Training Equipment Educational Equipment for college, university, technical schools.
losses in a pipe system Vocational Training Equipment Educational Equipment
SR3005 losses in a pipe system Vocational Training Equipment Educational Equipment
Brand: ShouldShine
Model:SR3005
Learning Objectives / Experiments
– pressure curve in a closed pipe system with circulation pump
– influence of pipe diameter, flow velocity, change in
cross-section and pipe fittings on the pressure losses
– determination of pump characteristics, system characteristics and the operating point
Specification
[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] closed water circuit with pump and tank
[5] integrated bleed valve on manometer and in the pipe section
[6] flow measurement using rotameter
[7] measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Technical Data
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 140kg
Required for Operation
230V, 50Hz, 1 phaseFour way mixing valve training panel Educational Equipment Teaching Equipment
SR3006 Four way mixing valve training panel Educational Equipment Teaching Equipment for college, university.
Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
SR2022 Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
Brand: ShouldShine
Model: SR2022
Learning Objectives / Experiments
– Variables affecting energy efficiency
* controller parameters
* refrigerant supercooling
– Interconnected operation of compressors
– Operation of a multicompressor controller
– Methods for returning oil in a multicompressor refrigeration system
– Representation of the thermodynamic cycle in the log p-h diagramSpecification
[1] Refrigeration system in multicompressor operation to investigate energy efficiency
[2] Refrigeration circuit with 3 compressors connected in parallel, condenser, thermostatic expansion valve and coaxial coil heat exchanger as evaporator
[3] Heat exchanger for refrigerant supercooling can be added via valves
[4] Glycol-water circuit includes pump and tank with heater serving as cooling load at the evaporator
[5] Multicompressor controller for the parallel operation of the compressors
[6] Separation of oil from the refrigerant on the delivery side and return to the intake side of the compressors
[7] Fan at the condenser with adjustable speed
[8] LabVIEW software for data acquisition via USB under Windows XP or Windows Vista
[9] Refrigerant R134a, CFC-free
Technical Data
3 compressors
– refrigeration capacity: each 1584W at -10°C/55°C
– power consumption: each 1156W at -10°C/55°C
Condenser with fan
– capacity: 4100W
– air flow: 1250m³/h
Coaxial coil heat exchanger capacity
– 4kW at ΔT=9K; 0,6m³/h glycol-water mixture
Glycol-water mixture pump
– max. flow rate: 5m³/h
– max. head: 6m
Heater power: 3kW
Tank
– glycol-water mixture: 23L
– refrigeration circuit receiver: 5,8L
Measuring ranges
– temperature: 4x 0…100°C, 4x -100°C…100°C
– pressure: 1x -1…9bar, 1x -1…24bar
– flow rate: 1x 1..25L/min
– compressor power: 0…4995W
Dimensions and Weight
l x w x h: 1800x700x1900mm
Weight: approx. 300kg
Connections
400V, 50/60Hz, 3 phasesInstallation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainInstallation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drainPlate Heat Exchanger Thermal Trainer Vocational Training Equipment
SR1158E Plate Heat Exchanger Thermal Trainer Vocational Training Equipment
I.Production profile
The key feature of plate heat exchangers is their compact design, in which optimum use is made of all of the material for heat transfer. The pressed in profile on the plates creates narrow flow channels, in which significant turbulence occurs. The turbulent flow allows effective heat transfer even with low flow rates and also has a self-cleaning effect. Plate heat exchangers are used in the food industry, offshore technology, refrigeration and domestic engineering.
II.Equipment feature
The SR1158E Plate Heat Exchanger is part of a series of units enabling experiments to be performed on different heat exchanger types. The experimental unit is ideally suited for investigating the functioning and behaviour of a plate heat exchanger in operation.
The plate heat exchanger is made up of profiled plates with water flowing through the spaces between them. The plates are soldered in such a way that two separate flow channels are formed. These are one “cold” and one “hot” flow channel, in an alternating arrangement. Part of the thermal energy of the hot water is transferred to the cold water. Valves on the supply unit are used to adjust the flow rates of hot and cold water. The supply hose can be reconnected using quick-release couplings, allowing the flow direction to be reversed. This allows parallel flow or counter flow operationspecification
[1] plate heat exchanger for connection
[2] hot and cold water supply
[3] parallel flow and counterflow operation possible
[4] six soldered plates
[5] recording of temperature
Technical Data
6 plates, stainless steel
Heat transfer area: 480cm²
Dimensions and Weight
LxWxH: 400x230x85mm
Weight: approx. 3kg
Brand: ShouldShine
Model: SR1158E