Valves loss training panel Thermal Training Panel Didactic Equipment
ZF1120A Valves loss training panel Thermal Training Panel Didactic Equipment for college, university, vocational training centers.
- Description
- Inquiry
ZF1120A Valves loss training panel Thermal Training Panel Didactic Equipment
I.Equipment overview
The equipment can be used to verify the loss of fluid pressure by various valves.
The equipment uses an aluminum profile bracket to reduce the weight of the equipment while increasing the stability of the equipment. There are four handles on both sides of the device, and four universal wheels on the bottom of the device to facilitate equipment movement.
By observing the flow meter and the digital differential pressure gauge, the pressure loss data of the valve and the current flow data can be obtained intuitively and conveniently.
II.Equipment feature
The equipment uses high quality transparent PVC ball valve, a galvanized brass ball valve, a diversion system shut-off valve, a plug valve and a gate valve. Basically covers all types of valves.
Fully transparent flow meter, digital display differential pressure gauge for easy observation.
The device is controlled by a ball valve and can be freely selected for one or more valves for experimentation.
The device is easy to move, simple and durable.
Related Products
losses in a pipe system Vocational Training Equipment Educational Equipment
SR3005 losses in a pipe system Vocational Training Equipment Educational Equipment
Brand: ShouldShine
Model:SR3005
Learning Objectives / Experiments
– pressure curve in a closed pipe system with circulation pump
– influence of pipe diameter, flow velocity, change in
cross-section and pipe fittings on the pressure losses
– determination of pump characteristics, system characteristics and the operating point
Specification
[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] closed water circuit with pump and tank
[5] integrated bleed valve on manometer and in the pipe section
[6] flow measurement using rotameter
[7] measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Technical Data
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 140kg
Required for Operation
230V, 50Hz, 1 phasePlate Heat Exchanger Thermal Trainer Vocational Training Equipment
SR1158E Plate Heat Exchanger Thermal Trainer Vocational Training Equipment
I.Production profile
The key feature of plate heat exchangers is their compact design, in which optimum use is made of all of the material for heat transfer. The pressed in profile on the plates creates narrow flow channels, in which significant turbulence occurs. The turbulent flow allows effective heat transfer even with low flow rates and also has a self-cleaning effect. Plate heat exchangers are used in the food industry, offshore technology, refrigeration and domestic engineering.
II.Equipment feature
The SR1158E Plate Heat Exchanger is part of a series of units enabling experiments to be performed on different heat exchanger types. The experimental unit is ideally suited for investigating the functioning and behaviour of a plate heat exchanger in operation.
The plate heat exchanger is made up of profiled plates with water flowing through the spaces between them. The plates are soldered in such a way that two separate flow channels are formed. These are one “cold” and one “hot” flow channel, in an alternating arrangement. Part of the thermal energy of the hot water is transferred to the cold water. Valves on the supply unit are used to adjust the flow rates of hot and cold water. The supply hose can be reconnected using quick-release couplings, allowing the flow direction to be reversed. This allows parallel flow or counter flow operationspecification
[1] plate heat exchanger for connection
[2] hot and cold water supply
[3] parallel flow and counterflow operation possible
[4] six soldered plates
[5] recording of temperature
Technical Data
6 plates, stainless steel
Heat transfer area: 480cm²
Dimensions and Weight
LxWxH: 400x230x85mm
Weight: approx. 3kg
Brand: ShouldShine
Model: SR1158EThermal Expansion Training Panel Educational Equipment Vocational Training Equipment
SR3002 Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
Brand: ShouldShine
Model:SR3002
Learning Objectives / Experiments
– thermal expansion of different materials such as PVC, PE, copper and steel
– determination of thermal expansion coefficients and the expansion force
– measurement of pipe elongation
– effect of varying pipe diameter
– expansion compensator
Specification
[1] investigating the thermal expansion of different pipe sections
[2] pipe sections can be selected by ball valves
[3] water connections made using quick-release couplings
[4] operation with hot and cold water supplies
[5] adjustment of the water temperature using mixing battery with thermocouple
[6] temperature measurement using battery-operated digital thermometer
[7] force measuring device to determine the expansion force
Technical Data
Pipe section length: 1000mm
Nominal diameters- PVC, PE, Cu: – Cu: – Steel: 1/2″
Mixing battery connection: 1/2″
Force measuring device
– spring rate per spring: 78N/mm
– total spring rate c: 156N/mm
Measuring range
– temperature: -50…90°C
Dimensions and Weight
LxWxH: 1650x700x1850mm
Weight: approx. 100kg
Required for Operation
Cold and hot water connectionRadiator training panel heat transfer trainer thermal lab equipment
SR3008 Radiator training panel heat transfer trainer thermal lab equipment for college, university, vocational schools.
Central Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BRadiator Training Panel Vocational Training Equipment Thermal Trainer
ZA1118A Radiator Training Panel Vocational Training Equipment Thermal Trainer
Description
The panel contains a pipe system with four radiators. Each radiator has an air bleed, a thermostatic valve and lockshield valve.
Rotameters indicate the flow rate through each individual radiator and for the entire system. Connections for cooling water make it possible to dissipate the heat supplied by the hot water. All water connections are made using quick-release couplings.
Training panel on heating systems and plumbing
•4 radiators with thermostatic valve, air bleed and adjustable lock shield valve
• 5 Rota meters
• 2 water connections for boiler DN15
• 2 cooling water connections DN15
• Water connections made using quick action hose couplings
• Hot and cold water supply
•Rota meters: 1x 1000ltr/h 4x 300ltr/h
• Radiator: plate heat exchanger with 10 plates, capacity: 3kW
Brand: Shouldshine
Model:ZF1118ATrainer Tubular Heat Exchanger Thermal Lab Equipment Educational Equipment
SR-WL302 Trainer Tubular Heat Exchanger Educational Equipment. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Hydronic balancing of radiators Technical Training Equipment Thermal Trainer
SR3009 Hydronic balancing of radiators Technical Training Equipment Thermal Trainer for college, university.
ZM6152 Heat Exchangers in the Refrigeration Circuit Technical Teaching Equipment
Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment,air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Expansion vessel training panel Vocational Training Equipment
SR3007 Expansion vessel training panel Vocational Training Equipment Teaching Equipment for college, university.