Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment
TB230324S02 Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment for college, vocational training center, university.
- Description
- Inquiry
TB230324S02 Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment
A SELF CONTAINED BENCH TOP UNIT FOR DEMONSTRATION OF A HEAT EXCHANGER. THE UNIT SHALL HAVE
- A) FINNED HEAT EXCHANGER (WATER TO AIR) WITH MINIMUM OF 15 TUBES.
- B) SHALL COMPRISE OF HOT WATER SYSTEM AND A COOLING AIR DUCT
C)HOT WATER SYSTEM: TANK WITH A PID CONTROLLED ELECTRIC HEATER, PUMP, TANK LEVEL INDICATOR,ELECTRICALLY OPERATED VAVE TO THE TANK INLET FOR FILLING OF WATER,A NEEDLE VALVE AND A FLOW METER TO CONTROL AND MEASURE THE FLOW RATE.
THE TANK NEEDS TO HAVE SAFETY PROTECTIONS AGAINST LOW/HIGH WATER LEVELS AND OVERTEMPERATURE.
D)COOLING AIR DUCT: THE AIR INLET SHALL BE A VERTICAL DUCT CONTAINING AN ORIFICE PLATE WHICH CONNECTS TO A DIFFERENTIAL PRESSURE TRANSDUCER. THE AIR THEN PASSES THRO’ A FIXED SPEED CENTRIFUGAL FAN.
THE FAN OUTLET AIR FLOWS THRO’ THE HEAT EXCHANGER. AIR EXIT FROM THE DUCT IS CONTROLLED BY A MANUALLY OPERATED SLIDE VALVE. STUDENTS TO USE THE ORIFICE AND SLIDE VALVE TO CONTROL THE AIR FLOW RATE.
- E) HEAT EXCHANGERS TO HAVE TRANSPARENT SIDES. THE UNIT TO HAVE SELF SEALING QUICK CONNECTING FITTINGS WHICH USES NO TOOLS.
- F) THERMOCUPLES AT THE WATER INLET/OUTLETS AND AIR INLET/OUTLETS TO MEASURE FLUID STREAM TEMPERATURES.
- F) DIGITAL DISPLAY OF TEMPERATURES, WATER FLOW RATE AND ORIFICECE PRESSURE
Related Products
Thermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
ZF1116A Thermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
Brand: Shouldshine
Model:ZF1116A
Specification
Training panel for investigating the thermal expansion of different pipe sections
• Length of each pipe section 1200mm
• Pipe sections can be selected by ball valves
• Water connections made using quick action hose couplings
• Operation with hot and cold water supplies
• Adjustment of the water temperature using mixing battery with thermocouple
• Temperature measurement using battery-operated digital thermometer
• Force measuring device to determine the expansion force
• Pipe section length: 1000mm
• Nominal diameters: – PVC, PE, Cu: DN15 – Cu: DN8 – Steel: 1/2″
• Mixing battery connection: 1/2″
• Force measuring device: – spring rate per spring: 78N/mm – total spring rate c: 156N/mmTrainer Tubular Heat Exchanger Thermal Lab Equipment Educational Equipment
SR-WL302 Trainer Tubular Heat Exchanger Educational Equipment. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
SR2022 Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
Brand: ShouldShine
Model: SR2022
Learning Objectives / Experiments
– Variables affecting energy efficiency
* controller parameters
* refrigerant supercooling
– Interconnected operation of compressors
– Operation of a multicompressor controller
– Methods for returning oil in a multicompressor refrigeration system
– Representation of the thermodynamic cycle in the log p-h diagramSpecification
[1] Refrigeration system in multicompressor operation to investigate energy efficiency
[2] Refrigeration circuit with 3 compressors connected in parallel, condenser, thermostatic expansion valve and coaxial coil heat exchanger as evaporator
[3] Heat exchanger for refrigerant supercooling can be added via valves
[4] Glycol-water circuit includes pump and tank with heater serving as cooling load at the evaporator
[5] Multicompressor controller for the parallel operation of the compressors
[6] Separation of oil from the refrigerant on the delivery side and return to the intake side of the compressors
[7] Fan at the condenser with adjustable speed
[8] LabVIEW software for data acquisition via USB under Windows XP or Windows Vista
[9] Refrigerant R134a, CFC-free
Technical Data
3 compressors
– refrigeration capacity: each 1584W at -10°C/55°C
– power consumption: each 1156W at -10°C/55°C
Condenser with fan
– capacity: 4100W
– air flow: 1250m³/h
Coaxial coil heat exchanger capacity
– 4kW at ΔT=9K; 0,6m³/h glycol-water mixture
Glycol-water mixture pump
– max. flow rate: 5m³/h
– max. head: 6m
Heater power: 3kW
Tank
– glycol-water mixture: 23L
– refrigeration circuit receiver: 5,8L
Measuring ranges
– temperature: 4x 0…100°C, 4x -100°C…100°C
– pressure: 1x -1…9bar, 1x -1…24bar
– flow rate: 1x 1..25L/min
– compressor power: 0…4995W
Dimensions and Weight
l x w x h: 1800x700x1900mm
Weight: approx. 300kg
Connections
400V, 50/60Hz, 3 phasesRadiator Training Panel Vocational Training Equipment Thermal Trainer
ZA1118A Radiator Training Panel Vocational Training Equipment Thermal Trainer
Description
The panel contains a pipe system with four radiators. Each radiator has an air bleed, a thermostatic valve and lockshield valve.
Rotameters indicate the flow rate through each individual radiator and for the entire system. Connections for cooling water make it possible to dissipate the heat supplied by the hot water. All water connections are made using quick-release couplings.
Training panel on heating systems and plumbing
•4 radiators with thermostatic valve, air bleed and adjustable lock shield valve
• 5 Rota meters
• 2 water connections for boiler DN15
• 2 cooling water connections DN15
• Water connections made using quick action hose couplings
• Hot and cold water supply
•Rota meters: 1x 1000ltr/h 4x 300ltr/h
• Radiator: plate heat exchanger with 10 plates, capacity: 3kW
Brand: Shouldshine
Model:ZF1118Alosses in a pipe system Vocational Training Equipment Educational Equipment
SR3005 losses in a pipe system Vocational Training Equipment Educational Equipment
Brand: ShouldShine
Model:SR3005
Learning Objectives / Experiments
– pressure curve in a closed pipe system with circulation pump
– influence of pipe diameter, flow velocity, change in
cross-section and pipe fittings on the pressure losses
– determination of pump characteristics, system characteristics and the operating point
Specification
[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] closed water circuit with pump and tank
[5] integrated bleed valve on manometer and in the pipe section
[6] flow measurement using rotameter
[7] measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Technical Data
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 140kg
Required for Operation
230V, 50Hz, 1 phasePlate Heat Exchanger Thermal Trainer Vocational Training Equipment
SR1158E Plate Heat Exchanger Thermal Trainer Vocational Training Equipment
I.Production profile
The key feature of plate heat exchangers is their compact design, in which optimum use is made of all of the material for heat transfer. The pressed in profile on the plates creates narrow flow channels, in which significant turbulence occurs. The turbulent flow allows effective heat transfer even with low flow rates and also has a self-cleaning effect. Plate heat exchangers are used in the food industry, offshore technology, refrigeration and domestic engineering.
II.Equipment feature
The SR1158E Plate Heat Exchanger is part of a series of units enabling experiments to be performed on different heat exchanger types. The experimental unit is ideally suited for investigating the functioning and behaviour of a plate heat exchanger in operation.
The plate heat exchanger is made up of profiled plates with water flowing through the spaces between them. The plates are soldered in such a way that two separate flow channels are formed. These are one “cold” and one “hot” flow channel, in an alternating arrangement. Part of the thermal energy of the hot water is transferred to the cold water. Valves on the supply unit are used to adjust the flow rates of hot and cold water. The supply hose can be reconnected using quick-release couplings, allowing the flow direction to be reversed. This allows parallel flow or counter flow operationspecification
[1] plate heat exchanger for connection
[2] hot and cold water supply
[3] parallel flow and counterflow operation possible
[4] six soldered plates
[5] recording of temperature
Technical Data
6 plates, stainless steel
Heat transfer area: 480cm²
Dimensions and Weight
LxWxH: 400x230x85mm
Weight: approx. 3kg
Brand: ShouldShine
Model: SR1158EHeat Transfer Bench Educational Equipment Thermal Training Equipment
SR1162E Heat Transfer Trainer Heat Transfer Bench Educational Equipment Thermal Training Equipment
1 Product Overview
1.1 Profile
This product is an extensible educational experiment equipment for students to observe the heating, cooling and air movement of the device during operation. Students can observe the mixing of air and conduct tests to monitor temperature and air pressure. Grasp its control principle and control method, cultivate students’ corresponding knowledge and skills, suitable for higher vocational schools, engineering university, secondary vocational school and technical school related professional teaching and skills training evaluation.
1.2 Feature
(1) The training platform adopts an aluminum column frame structure with a universal wheel at the bottom for flexible movement. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful. The instrument and power supply are integrated and installed, which is easy to use and not easily damaged.
(2) The training platform has a good safety protection system.
2 Technical specifications
(1) Input Power: AC220V±10% 60Hz
(2) Fan: Supply voltage: AC220V/50Hz Power: 1.5kW; Maximum flow rate: 2.160m3/h
(3) Overall dimensions: 2000mm x 750mm x 2100mm
(4) Overall capacity: <2.5KVA
(5) Weight: <100kg
(6) Working conditions: Ambient temperature -10°C to +40°C Relative humidity <85% (25°C)
3 Product introduction
3.1 Power control panel
(1)The power control panel adopts an aluminum alloy frame and a closed box structure, which is integrated with the placement rack below.
(2)Configured with circuit breaker, power indicator, temperature adjustment knob, thermometer, power socket, differential pressure gauge, thermostat and intelligent electrical parameter measuring instrument
(3)The power input is controlled by the leakage breaker and the emergency stop control button is provided. In case of emergency, you press emergency stop button is so as to cut off the power.
3.2 Training workbench
(1)Training workbench:
The training table is supported by aluminum pillars, and the bottom universal wheel has a brake that can be moved and positioned flexibly. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful.
(2) Heat exchange systemValves loss training panel Thermal Training Panel Didactic Equipment
ZF1120A Valves loss training panel Thermal Training Panel Didactic Equipment for college, university, vocational training centers.
Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drainFour way mixing valve training panel Educational Equipment Teaching Equipment
SR3006 Four way mixing valve training panel Educational Equipment Teaching Equipment for college, university.