Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment
TB230324S02 Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment for college, vocational training center, university.
- Description
- Inquiry
TB230324S02 Finned Tube Heat Exchanger Teaching Equipment Heat Transfer Lab Equipment
A SELF CONTAINED BENCH TOP UNIT FOR DEMONSTRATION OF A HEAT EXCHANGER. THE UNIT SHALL HAVE
- A) FINNED HEAT EXCHANGER (WATER TO AIR) WITH MINIMUM OF 15 TUBES.
- B) SHALL COMPRISE OF HOT WATER SYSTEM AND A COOLING AIR DUCT
C)HOT WATER SYSTEM: TANK WITH A PID CONTROLLED ELECTRIC HEATER, PUMP, TANK LEVEL INDICATOR,ELECTRICALLY OPERATED VAVE TO THE TANK INLET FOR FILLING OF WATER,A NEEDLE VALVE AND A FLOW METER TO CONTROL AND MEASURE THE FLOW RATE.
THE TANK NEEDS TO HAVE SAFETY PROTECTIONS AGAINST LOW/HIGH WATER LEVELS AND OVERTEMPERATURE.
D)COOLING AIR DUCT: THE AIR INLET SHALL BE A VERTICAL DUCT CONTAINING AN ORIFICE PLATE WHICH CONNECTS TO A DIFFERENTIAL PRESSURE TRANSDUCER. THE AIR THEN PASSES THRO’ A FIXED SPEED CENTRIFUGAL FAN.
THE FAN OUTLET AIR FLOWS THRO’ THE HEAT EXCHANGER. AIR EXIT FROM THE DUCT IS CONTROLLED BY A MANUALLY OPERATED SLIDE VALVE. STUDENTS TO USE THE ORIFICE AND SLIDE VALVE TO CONTROL THE AIR FLOW RATE.
- E) HEAT EXCHANGERS TO HAVE TRANSPARENT SIDES. THE UNIT TO HAVE SELF SEALING QUICK CONNECTING FITTINGS WHICH USES NO TOOLS.
- F) THERMOCUPLES AT THE WATER INLET/OUTLETS AND AIR INLET/OUTLETS TO MEASURE FLUID STREAM TEMPERATURES.
- F) DIGITAL DISPLAY OF TEMPERATURES, WATER FLOW RATE AND ORIFICECE PRESSURE
Related Products
Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
SR3002 Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
Brand: ShouldShine
Model:SR3002
Learning Objectives / Experiments
– thermal expansion of different materials such as PVC, PE, copper and steel
– determination of thermal expansion coefficients and the expansion force
– measurement of pipe elongation
– effect of varying pipe diameter
– expansion compensator
Specification
[1] investigating the thermal expansion of different pipe sections
[2] pipe sections can be selected by ball valves
[3] water connections made using quick-release couplings
[4] operation with hot and cold water supplies
[5] adjustment of the water temperature using mixing battery with thermocouple
[6] temperature measurement using battery-operated digital thermometer
[7] force measuring device to determine the expansion force
Technical Data
Pipe section length: 1000mm
Nominal diameters- PVC, PE, Cu: – Cu: – Steel: 1/2″
Mixing battery connection: 1/2″
Force measuring device
– spring rate per spring: 78N/mm
– total spring rate c: 156N/mm
Measuring range
– temperature: -50…90°C
Dimensions and Weight
LxWxH: 1650x700x1850mm
Weight: approx. 100kg
Required for Operation
Cold and hot water connectionInstallation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainPlate Heat Exchanger Thermal Trainer Vocational Training Equipment
SR1158E Plate Heat Exchanger Thermal Trainer Vocational Training Equipment
I.Production profile
The key feature of plate heat exchangers is their compact design, in which optimum use is made of all of the material for heat transfer. The pressed in profile on the plates creates narrow flow channels, in which significant turbulence occurs. The turbulent flow allows effective heat transfer even with low flow rates and also has a self-cleaning effect. Plate heat exchangers are used in the food industry, offshore technology, refrigeration and domestic engineering.
II.Equipment feature
The SR1158E Plate Heat Exchanger is part of a series of units enabling experiments to be performed on different heat exchanger types. The experimental unit is ideally suited for investigating the functioning and behaviour of a plate heat exchanger in operation.
The plate heat exchanger is made up of profiled plates with water flowing through the spaces between them. The plates are soldered in such a way that two separate flow channels are formed. These are one “cold” and one “hot” flow channel, in an alternating arrangement. Part of the thermal energy of the hot water is transferred to the cold water. Valves on the supply unit are used to adjust the flow rates of hot and cold water. The supply hose can be reconnected using quick-release couplings, allowing the flow direction to be reversed. This allows parallel flow or counter flow operationspecification
[1] plate heat exchanger for connection
[2] hot and cold water supply
[3] parallel flow and counterflow operation possible
[4] six soldered plates
[5] recording of temperature
Technical Data
6 plates, stainless steel
Heat transfer area: 480cm²
Dimensions and Weight
LxWxH: 400x230x85mm
Weight: approx. 3kg
Brand: ShouldShine
Model: SR1158ECentral Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BPipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
ZF1117A Pipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
Brand: Shouldshine
Model:ZF1117A
Specification
[1] investigation of the pipe friction in laminar or turbulent flow on Hydraulic Bench
[2] transparent tank with overflow ensures constant water inlet pressure in the pipe section for experiments with laminar flow
[3] water supply via Base Module ( Hydraulic Bench) or via laboratory supply for experiments with turbulent flow
[4] flow rate adjustment via valves
[5] twin tube manometer for measurements in laminar flow
[6] dial-gauge manometer for measurements in turbulent flow
[7] flow rate determined by base module Hydraulic Bench
[8] water supply using base module ( Hydraulic Bench) or via laboratory supply
* Diameter of test pipe : 3.0mm ( Bore)
* Length of test pipe : 524mm
* Needle Valve included to regulate flow rate
length: 1000mm – Pipe section 1: acrylic 20×1.5mm – Pipe section 2: steel 1/2″ –
Smooth-bore pipes of various diameters Size – 6mm , 10mm, 17mm
Overall dimensions:
* Height : 1.05m form the ground level
* Width : 2.25m
* Depth : 0.43m
Test Pipe Diameters:
The Pipe network should have 90° Bends, 90° elbow,90°T, 45°elbow & Y.
Sudden enlargement
Sudden contraction
Ball Valve
Gate Valve
Globe valve
Inline strainer
Venturi made of clear acrylic
orifice palte made of clear acrylic
Pitot Static tube section made of clear acrylic
EXPERIMENTAL CAPABILITIES
Laminar to turbulent flow regimes in pipes
Energy losses in pipe fittings and bends
Flow measurement using venturi meter
Flow measurement using orifice plate
Use of pitot static tube
Use of manometersFitting Loss Training Panel Educational Equipment Vocational Training Equipment
ZF1119A Fitting Loss Training Panel Educational Equipment Vocational Training Equipment
Specification
Training panel for investigating the pressure losses in pipe fittings such as elbows and bends
4different measuring sections, measured length of each section 2300mm, 10 elbows/bends
Pressure measurement with annular chambers with electronic differential pressure gauge
Flow rate measurement with Rota meter
Hose connections made using quick action coupling
Water feed via pressure reducer
Cold water connection
Differential pressure gauge with bleed – measuring range: 0…2000mbar – supply: 9V, battery-operated
Rota meter: measuring range 150…1600ltr/h
Outlet pressure at pressure reducer: 0.5…2bar
Pipe sections: measured length: 2300mm – Pipe section 1: steel, bend
1/2″, 90° bend – Pipe section 3: copper 18x1mm, 90° elbow – Pipe section 4: copper 18x1mm, 90° bend
Pipe and Fittings
7mm bore test section
13.6mm bore test section
13.6mm bore test section with four bends
13.6mm bore test section with four elbows
13.6mm bore test section with ball valve
13.6mm bore test section with angle seated valve
Expeirmental Capabilities
Determination of pressure drop across various pipes and fittings at differnet flow rates
Flow rate/diameter relationship determination for flid flow in pipes
Estimation of loss coefficient (K) for various pipes, pipe fitting and valve settings
Friction Factor determination for fluid flow in smooth pipes
Brand: Shouldshine
Model:ZF1119AHeat Transfer Bench Educational Equipment Thermal Training Equipment
SR1162E Heat Transfer Trainer Heat Transfer Bench Educational Equipment Thermal Training Equipment
1 Product Overview
1.1 Profile
This product is an extensible educational experiment equipment for students to observe the heating, cooling and air movement of the device during operation. Students can observe the mixing of air and conduct tests to monitor temperature and air pressure. Grasp its control principle and control method, cultivate students’ corresponding knowledge and skills, suitable for higher vocational schools, engineering university, secondary vocational school and technical school related professional teaching and skills training evaluation.
1.2 Feature
(1) The training platform adopts an aluminum column frame structure with a universal wheel at the bottom for flexible movement. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful. The instrument and power supply are integrated and installed, which is easy to use and not easily damaged.
(2) The training platform has a good safety protection system.
2 Technical specifications
(1) Input Power: AC220V±10% 60Hz
(2) Fan: Supply voltage: AC220V/50Hz Power: 1.5kW; Maximum flow rate: 2.160m3/h
(3) Overall dimensions: 2000mm x 750mm x 2100mm
(4) Overall capacity: <2.5KVA
(5) Weight: <100kg
(6) Working conditions: Ambient temperature -10°C to +40°C Relative humidity <85% (25°C)
3 Product introduction
3.1 Power control panel
(1)The power control panel adopts an aluminum alloy frame and a closed box structure, which is integrated with the placement rack below.
(2)Configured with circuit breaker, power indicator, temperature adjustment knob, thermometer, power socket, differential pressure gauge, thermostat and intelligent electrical parameter measuring instrument
(3)The power input is controlled by the leakage breaker and the emergency stop control button is provided. In case of emergency, you press emergency stop button is so as to cut off the power.
3.2 Training workbench
(1)Training workbench:
The training table is supported by aluminum pillars, and the bottom universal wheel has a brake that can be moved and positioned flexibly. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful.
(2) Heat exchange systemZM6152 Heat Exchangers in the Refrigeration Circuit Technical Teaching Equipment
Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment,air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Installation technology: losses in a pipe system Educational Equipment
SR3005 Installation technology: losses in a pipe system Technical Training Equipment Educational Equipment for college, university, technical schools.
Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drain