Temperature Measurement Calibration Units Educational Equipment Thermal Laboratory Equipment
TB230324S01 Temperature Measurement Calibration Units Educational Equipment Thermal Laboratory Equipment for college, vocational training center, university.
- Description
- Inquiry
TB230324S01 Temperature Measurement Calibration Units Educational Equipment Thermal Laboratory Equipment
TABLETOP UNIT FOR LEARNING FUNDAMENTALS OF TEMPERATURE MEASUREMENT BY EXPERIMENTATION. THE UNIT SHALL BE CAPABLE OF FAMILIARISING THE STUDENT OF VARIOUS METHODS OF TEMPERATURE MEASUREMENT SUCH AS
- a) NON-ELECTRICAL METHODS: GAS AND LIQUID FILLED THERMOMETERS, BIMETALLIC THERMOMETERS AND TEMPERATURE MEASURING STRIPS
- b) ELECTRIC METHODS: THERMOCOUPLE,RESISTANCE TEMPERATURE DETECTOR Pt100,THERMISTOR
c)MEASURING RH OF AIR BY A PSYCHROMETER
- d) CALIBRATING OF ELECTRIC TEMPERATURE SENSORS
THE EQUIPMENT SHALL CONSISTS OF
- a) LIQUID(-10-250℃),BIMETALLIC AND GAS PRESSURE THERMOMETRS(0-200℃)
- b) TEMPERATURE SENSORS: THERMOCUPLE TYPE K (0-1000℃)
c)RESISTANCE TEMPERATURE DETECTOR Pt 100 (0-100℃)
d)THERMISTOR NTC (20-55℃)
d)TEMPERATURE MEASURING STRIPS (29-290℃)
- e) HEAT SOURCES: IMMERSION HEATER(300W), HEATER WITH THERMOSTAT(450W AND MAX. TEMPERATURE-425℃),VACCUM FLASK 1L
- f) CALIBRATION UNITS: PRECISION RESISTORS (10Ώ,100Ώ,1000Ώ) AND DIGITAL MULTIMETER
- g) PSYCHROMETER FOR RH MEASUREMENT
Related Products
Four way mixing valve training panel Educational Equipment Teaching Equipment
SR3006 Four way mixing valve training panel Educational Equipment Teaching Equipment for college, university.
Central Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BInstallation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drainTrainer for Various Heat Exchangers Thermal Lab Equipment Educational Equipment
ZF1115A Trainer for Various Heat Exchangers Thermal Lab Equipment Educational Equipment
Specification
[1] examination and comparison of various heat exchanger types
[2] five different types of heat exchangers included in the scope of delivery
[3] finned heat exchanger with fan
[4] operating mode (parallel flow or counter flow) selectable via valves
[5] flow rates adjustable via valves
[6] electromagnetic flow meter
[7] digital displays for temperature, pressure differences and flow rate
[8] hot & cold water benches available for
independent operation
[9] water/steam heat exchanger unit and electrical steam
Generator available for further experiments
[10] software for data acquisition via USB under Windows Vista or
Windows 7
Technical Data
Plate heat exchanger, 10 plates
– heat transfer surface area: approx. 0,26m²
– capacity: 15kW
Tubular heat exchanger
– heat transfer surface area: 0,1m²
– heat transfer surface area (coil): 0,17m²
Shell and tube heat exchanger
– capacity: 13kW
Finned cross-flow heat exchanger
– heat transfer surface area: approx. 2,8m²
– max. flow rate fan: 780m³/h
– max. pressure difference fan: 430Pa
Jacketed vessel with stirrer
– heat transfer surface area (vessel): 0,16m²
– heat transfer surface area (coil): 0,17m²
Measuring ranges
– differential pressure air: 0…10mbar
– differential pressure water: 0…1000mbar
– flow rate: 0…3m³/h
– temperature: 0…100°C
Dimensions and Weight
LxWxH: 2010x800x1760mm
Weight: approx. 300kgBrand: Shouldshine
Model:ZF1115AInstallation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainPipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
ZF1117A Pipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
Brand: Shouldshine
Model:ZF1117A
Specification
[1] investigation of the pipe friction in laminar or turbulent flow on Hydraulic Bench
[2] transparent tank with overflow ensures constant water inlet pressure in the pipe section for experiments with laminar flow
[3] water supply via Base Module ( Hydraulic Bench) or via laboratory supply for experiments with turbulent flow
[4] flow rate adjustment via valves
[5] twin tube manometer for measurements in laminar flow
[6] dial-gauge manometer for measurements in turbulent flow
[7] flow rate determined by base module Hydraulic Bench
[8] water supply using base module ( Hydraulic Bench) or via laboratory supply
* Diameter of test pipe : 3.0mm ( Bore)
* Length of test pipe : 524mm
* Needle Valve included to regulate flow rate
length: 1000mm – Pipe section 1: acrylic 20×1.5mm – Pipe section 2: steel 1/2″ –
Smooth-bore pipes of various diameters Size – 6mm , 10mm, 17mm
Overall dimensions:
* Height : 1.05m form the ground level
* Width : 2.25m
* Depth : 0.43m
Test Pipe Diameters:
The Pipe network should have 90° Bends, 90° elbow,90°T, 45°elbow & Y.
Sudden enlargement
Sudden contraction
Ball Valve
Gate Valve
Globe valve
Inline strainer
Venturi made of clear acrylic
orifice palte made of clear acrylic
Pitot Static tube section made of clear acrylic
EXPERIMENTAL CAPABILITIES
Laminar to turbulent flow regimes in pipes
Energy losses in pipe fittings and bends
Flow measurement using venturi meter
Flow measurement using orifice plate
Use of pitot static tube
Use of manometersHeat Transfer Bench Educational Equipment Thermal Training Equipment
SR1162E Heat Transfer Trainer Heat Transfer Bench Educational Equipment Thermal Training Equipment
1 Product Overview
1.1 Profile
This product is an extensible educational experiment equipment for students to observe the heating, cooling and air movement of the device during operation. Students can observe the mixing of air and conduct tests to monitor temperature and air pressure. Grasp its control principle and control method, cultivate students’ corresponding knowledge and skills, suitable for higher vocational schools, engineering university, secondary vocational school and technical school related professional teaching and skills training evaluation.
1.2 Feature
(1) The training platform adopts an aluminum column frame structure with a universal wheel at the bottom for flexible movement. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful. The instrument and power supply are integrated and installed, which is easy to use and not easily damaged.
(2) The training platform has a good safety protection system.
2 Technical specifications
(1) Input Power: AC220V±10% 60Hz
(2) Fan: Supply voltage: AC220V/50Hz Power: 1.5kW; Maximum flow rate: 2.160m3/h
(3) Overall dimensions: 2000mm x 750mm x 2100mm
(4) Overall capacity: <2.5KVA
(5) Weight: <100kg
(6) Working conditions: Ambient temperature -10°C to +40°C Relative humidity <85% (25°C)
3 Product introduction
3.1 Power control panel
(1)The power control panel adopts an aluminum alloy frame and a closed box structure, which is integrated with the placement rack below.
(2)Configured with circuit breaker, power indicator, temperature adjustment knob, thermometer, power socket, differential pressure gauge, thermostat and intelligent electrical parameter measuring instrument
(3)The power input is controlled by the leakage breaker and the emergency stop control button is provided. In case of emergency, you press emergency stop button is so as to cut off the power.
3.2 Training workbench
(1)Training workbench:
The training table is supported by aluminum pillars, and the bottom universal wheel has a brake that can be moved and positioned flexibly. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful.
(2) Heat exchange systemFitting Loss Training Panel Educational Equipment Vocational Training Equipment
ZF1119A Fitting Loss Training Panel Educational Equipment Vocational Training Equipment
Specification
Training panel for investigating the pressure losses in pipe fittings such as elbows and bends
4different measuring sections, measured length of each section 2300mm, 10 elbows/bends
Pressure measurement with annular chambers with electronic differential pressure gauge
Flow rate measurement with Rota meter
Hose connections made using quick action coupling
Water feed via pressure reducer
Cold water connection
Differential pressure gauge with bleed – measuring range: 0…2000mbar – supply: 9V, battery-operated
Rota meter: measuring range 150…1600ltr/h
Outlet pressure at pressure reducer: 0.5…2bar
Pipe sections: measured length: 2300mm – Pipe section 1: steel, bend
1/2″, 90° bend – Pipe section 3: copper 18x1mm, 90° elbow – Pipe section 4: copper 18x1mm, 90° bend
Pipe and Fittings
7mm bore test section
13.6mm bore test section
13.6mm bore test section with four bends
13.6mm bore test section with four elbows
13.6mm bore test section with ball valve
13.6mm bore test section with angle seated valve
Expeirmental Capabilities
Determination of pressure drop across various pipes and fittings at differnet flow rates
Flow rate/diameter relationship determination for flid flow in pipes
Estimation of loss coefficient (K) for various pipes, pipe fitting and valve settings
Friction Factor determination for fluid flow in smooth pipes
Brand: Shouldshine
Model:ZF1119ATrainer Tubular Heat Exchanger Thermal Lab Equipment Educational Equipment
SR-WL302 Trainer Tubular Heat Exchanger Educational Equipment. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Installation technology: losses in a pipe system Educational Equipment
SR3005 Installation technology: losses in a pipe system Technical Training Equipment Educational Equipment for college, university, technical schools.