ZMP2106 Double Side Electro Pneumatic Training Workbench Teaching Equipment

ZMP2106 Double Side Electro Pneumatic Training Workbench Teaching Equipment

ZMP2106 Double Side Electro Pneumatic Training Workbench Teaching Equipment for college, university.

  • Description
  • Inquiry

ZMP2106 Double Side Electro Pneumatic Training Workbench Teaching Equipment

Pneumatic and electropneumatic dynamometer Double sided mobile workstation allows mounting and operation of different components without tool use (components equipped with quick mounting system)

1* Dimensional roll table between length 1200 mm, height 1700 mm and depth 800 mm

1* extruded and adonized aluminium plate between length 1080 mm and depth 680 mm with possibility of attaching electrical components to both sides

2*four drawer box with key for closing

1*cable guide

1 x electrical power units for mounting frame 220V AC- 24 VDC/ 4A minimum with 6 outputs

1 x lubricated silent compressor for classroom use: pressure protected and safety valve

– Power voltage 230V/50 HZ, Service pressure 7 bar.

 -Aspiration rate 40 L/MIN.

– Tank volume 9 l.

– Output with pressure regulator, pressure gauge and quick coupling.

– Manual and mechanical pre-pressurization actuator

– 2 3/2 NF valves operated by push button

– 2 Distributors 3/2 NO operated by push button

– 1 3/2 NF valve operated by emergency stop button

– 4 Distributors FC 3/2 NF operated per roller

– 2 3/2 NF distributors operated by retractable roller

– 1 3/2 NF bistable distributor operated by a switch

– 1 5/2 valve operated by push button

 -1 5/2 distributor with two-position selector

– 1 5/3 Distributor with closed centre control by clamping lever

– Pneumatic control pre-actuator

– 1 3/2 NF monostable distributor for pneumatic control

– 2 Pneumatic 5/2 monostable valves;

– 2 Distributors 5/2 bistable with pneumatic control

– Signal processing, flow control and locking

– 1 logic door “OR”

– 1 Circuit selector in “OR”

– 1 Logic door “ET”

– 1 “ET” circuit selector

– 2 unidirectional flow stranglers

– 1 Quick exhaust valve

– 1 positive output adjustable air timer

– 2 flow adjusters with anti-return valve driven

– 1 bidirectional flow strangler

– 1 Sequence valve

– Cylinders

– 2 Single effect spring cylinders

– 1 Dual magnetic piston cylinder and elastic damping

– Dual effect magnetic piston cylinder with adjustable pneumatic damping

– electrodistributors

– 1 Electrovalve 3/2 monostable NF (24 VDC coil with LED light)

– 1 3/2 bistable electrovalve (24 VDC coil with LED light)

– 2 5/2 bistable electrovalves (24 VDC coil with LED light)

– 2 5/2 monostable electrovalves (24 VDC coil with LED light)

– 1 5/3 centre closed electronics (24 VDC coil with LED light)

– 1 Vacuum generator by venturi effect with suction cup

– Control modules/detectors

– 1 ON/OFF switch

– 1 Emergency (Electric) Stop Push Button

1 set of electrical inputs (housing with 3 NO-NC push buttons)

– 1 set of 3 relays (3 NO-3 NC, reel 24VDC)

– 1 Indicator (Sights, bells)

– 1 set of 2 timer relays (2 NO- 2 NC)

– 1 electrical terminal block;

– 4 Reed type magnetic detectors

– 2 Static magnetic detectors;

– 1 Inductive detector

– 1 Capacitive detector

– 1 Photoelectric detector;

– 4 End of electric running

– 1 electrical contact pressure;

– Accessories

– Set of 10 “T” Fittings Ø 4mm

– Set of 10 plastic caps Ø 4mm

– Set of 10 “Y” fittings Ø 4mm

– 1x set of 4 mm secure laboratory cable (red and blue color) consisting of 80 minimum cables

We will contact you within 1 working day, please pay attention to the email.