Thermal Electrical Installation Trainer Plumbing and Sanitation Trainer Educational Equipment Heating and Ventilation Trainer
ZE4118B Thermal Electrical Installation Trainer Plumbing and Sanitation Trainer Educational Equipment Heating and Ventilation Trainer for university,college,technical institution, polytechnics.
- Description
- Inquiry
ZE4118B Thermal Electrical Installation Trainer Plumbing and Sanitation Trainer Educational Equipment Heating and Ventilation Trainer
Understand the principle of operation and the technologies of equipment and hydraulic circuits.
– Know how to put the installation into service:
– Safety instructions.
– Put in water.
– Start-up.
– Device settings
– Balancing.
– Know how to maintain an installation:
– Stop an installation.
– Disassembly and reassembly of equipment.
– Hydraulic and electrical wiring.
– Study and measure the hydraulic and electrical physical dimensions of the installation:
– Temperature, pressure, flow, heating law.
– Study on the expansion of heat transfer fluids.
– Voltage intensity, power absorbed.
– Perform balance sheets
Related Products
Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drainPlate Heat Exchanger Thermal Trainer Vocational Training Equipment
SR1158E Plate Heat Exchanger Thermal Trainer Vocational Training Equipment
I.Production profile
The key feature of plate heat exchangers is their compact design, in which optimum use is made of all of the material for heat transfer. The pressed in profile on the plates creates narrow flow channels, in which significant turbulence occurs. The turbulent flow allows effective heat transfer even with low flow rates and also has a self-cleaning effect. Plate heat exchangers are used in the food industry, offshore technology, refrigeration and domestic engineering.
II.Equipment feature
The SR1158E Plate Heat Exchanger is part of a series of units enabling experiments to be performed on different heat exchanger types. The experimental unit is ideally suited for investigating the functioning and behaviour of a plate heat exchanger in operation.
The plate heat exchanger is made up of profiled plates with water flowing through the spaces between them. The plates are soldered in such a way that two separate flow channels are formed. These are one “cold” and one “hot” flow channel, in an alternating arrangement. Part of the thermal energy of the hot water is transferred to the cold water. Valves on the supply unit are used to adjust the flow rates of hot and cold water. The supply hose can be reconnected using quick-release couplings, allowing the flow direction to be reversed. This allows parallel flow or counter flow operationspecification
[1] plate heat exchanger for connection
[2] hot and cold water supply
[3] parallel flow and counterflow operation possible
[4] six soldered plates
[5] recording of temperature
Technical Data
6 plates, stainless steel
Heat transfer area: 480cm²
Dimensions and Weight
LxWxH: 400x230x85mm
Weight: approx. 3kg
Brand: ShouldShine
Model: SR1158Elosses in a pipe system Vocational Training Equipment Educational Equipment
SR3005 losses in a pipe system Vocational Training Equipment Educational Equipment
Brand: ShouldShine
Model:SR3005
Learning Objectives / Experiments
– pressure curve in a closed pipe system with circulation pump
– influence of pipe diameter, flow velocity, change in
cross-section and pipe fittings on the pressure losses
– determination of pump characteristics, system characteristics and the operating point
Specification
[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] closed water circuit with pump and tank
[5] integrated bleed valve on manometer and in the pipe section
[6] flow measurement using rotameter
[7] measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Technical Data
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 140kg
Required for Operation
230V, 50Hz, 1 phaseTrainer Tubular Heat Exchanger Thermal Lab Equipment Educational Equipment
SR-WL302 Trainer Tubular Heat Exchanger Educational Equipment. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainTrainer for Various Heat Exchangers Thermal Lab Equipment Educational Equipment
ZF1115A Trainer for Various Heat Exchangers Thermal Lab Equipment Educational Equipment
Specification
[1] examination and comparison of various heat exchanger types
[2] five different types of heat exchangers included in the scope of delivery
[3] finned heat exchanger with fan
[4] operating mode (parallel flow or counter flow) selectable via valves
[5] flow rates adjustable via valves
[6] electromagnetic flow meter
[7] digital displays for temperature, pressure differences and flow rate
[8] hot & cold water benches available for
independent operation
[9] water/steam heat exchanger unit and electrical steam
Generator available for further experiments
[10] software for data acquisition via USB under Windows Vista or
Windows 7
Technical Data
Plate heat exchanger, 10 plates
– heat transfer surface area: approx. 0,26m²
– capacity: 15kW
Tubular heat exchanger
– heat transfer surface area: 0,1m²
– heat transfer surface area (coil): 0,17m²
Shell and tube heat exchanger
– capacity: 13kW
Finned cross-flow heat exchanger
– heat transfer surface area: approx. 2,8m²
– max. flow rate fan: 780m³/h
– max. pressure difference fan: 430Pa
Jacketed vessel with stirrer
– heat transfer surface area (vessel): 0,16m²
– heat transfer surface area (coil): 0,17m²
Measuring ranges
– differential pressure air: 0…10mbar
– differential pressure water: 0…1000mbar
– flow rate: 0…3m³/h
– temperature: 0…100°C
Dimensions and Weight
LxWxH: 2010x800x1760mm
Weight: approx. 300kgBrand: Shouldshine
Model:ZF1115ARadiator training panel heat transfer trainer thermal lab equipment
SR3008 Radiator training panel heat transfer trainer thermal lab equipment for college, university, vocational schools.
Installation technology: losses in a pipe system Educational Equipment
SR3005 Installation technology: losses in a pipe system Technical Training Equipment Educational Equipment for college, university, technical schools.
Pipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
ZF1117A Pipe Friction Training Panel Thermal Teaching Equipment Educational Equipment
Brand: Shouldshine
Model:ZF1117A
Specification
[1] investigation of the pipe friction in laminar or turbulent flow on Hydraulic Bench
[2] transparent tank with overflow ensures constant water inlet pressure in the pipe section for experiments with laminar flow
[3] water supply via Base Module ( Hydraulic Bench) or via laboratory supply for experiments with turbulent flow
[4] flow rate adjustment via valves
[5] twin tube manometer for measurements in laminar flow
[6] dial-gauge manometer for measurements in turbulent flow
[7] flow rate determined by base module Hydraulic Bench
[8] water supply using base module ( Hydraulic Bench) or via laboratory supply
* Diameter of test pipe : 3.0mm ( Bore)
* Length of test pipe : 524mm
* Needle Valve included to regulate flow rate
length: 1000mm – Pipe section 1: acrylic 20×1.5mm – Pipe section 2: steel 1/2″ –
Smooth-bore pipes of various diameters Size – 6mm , 10mm, 17mm
Overall dimensions:
* Height : 1.05m form the ground level
* Width : 2.25m
* Depth : 0.43m
Test Pipe Diameters:
The Pipe network should have 90° Bends, 90° elbow,90°T, 45°elbow & Y.
Sudden enlargement
Sudden contraction
Ball Valve
Gate Valve
Globe valve
Inline strainer
Venturi made of clear acrylic
orifice palte made of clear acrylic
Pitot Static tube section made of clear acrylic
EXPERIMENTAL CAPABILITIES
Laminar to turbulent flow regimes in pipes
Energy losses in pipe fittings and bends
Flow measurement using venturi meter
Flow measurement using orifice plate
Use of pitot static tube
Use of manometersValves loss training panel Thermal Training Panel Didactic Equipment
ZF1120A Valves loss training panel Thermal Training Panel Didactic Equipment for college, university, vocational training centers.