TB20230303R-002 Heat Convection And Radiator Appartus Educational Equipment

TB20230303R-002 Heat Convection And Radiator Appartus Educational Equipment

TB20230303R-002 Heat Convection And Radiator Appartus Educational Equipment for college, vocational training center, university. 

  • Description
  • Inquiry

TB20230303R-002 Heat Convection And Radiator Appartus Educational Equipment

Self-Contained Bench Top Apparatus, Suitable to Allow Student to Investigate Heat Transfer by Natural convection and radiation. The students shall be able to find the emissivity of a surface and verify the steffan-boltzaman  equation.

The Equipment shall consists of a pressure vessel facility to compress the vessel to 1 bar  (gauge) or evacuated down to 5pa (absolute) , Thermocouple , pressure transducers and A digital Display to Indicate Temperature, Pressures and power to the Heating Element.

A small Heated Element 20W Which Has A black Matt Surface Hangs in The Centre of the Pressure Vessel. A thermocouple is Attached to the Element to measure the Temperature. A thermocouple is fitted to the Vessel Wall to Measure the temperature in the vessel.

The Vessel Shall Be Subjected to Positive or Negative pressure Measurement.Two pressure sensors with suitable measuring ranges shall be available for pressure measurement   

Power : 250W, 230V

Description

Under real conditions, the heat transport between two objects is normally substance-bound, i.e. convection and/or heat conduction, and not substance-bound, i.e. radiation, at the same time. Determining the individual heat quantities of one type of transfer is difficult.

The trainer enables users to match the individual heat quantities to the corresponding type of transfer. The core element is a heated metal cylinder located at the centre of the pressure vessel. The surface temperature of the heated metal cylinder is controlled. Temperature sensors measure the surface temperature of the metal cylinder and the wall temperature of the pressure vessel. In addition to the heating power of the metal cylinder, it is possible to study the heat transport from the metal cylinder to the wall of the pressure vessel.

The pressure vessel can be put under vacuum or positive gauge pressure. In the vacuum, heat is transported primarily by radiation. If the vessel is filled with gas and is under positive gauge pressure, heat is also transferred by convection. It is possible to compare the heat transfer in different gases. In addition to air, nitrogen, helium, carbon dioxide or other gases are also suitable.

Heat transport by conduction is largely suppressed by adequately suspending the metal cylinder.

A rotary vane pump generates negative pressures down to approx. 0,02mbar. Positive gauge pressures up to approx. 1bar can be realised with compressed air. Two pressure sensors with suitable measuring ranges are available for the pressure measurement: a Pirani sensor measures the negative pressure while a piezo-resistive sensor measures the positive pressure.

The measured values can be read on digital displays. At the same time, the measured values can also be transmitted directly to a PC via USB, where they can be analysed with the software.

Specification

heat transfer between heated metal cylinder and vessel wall by convection and radiation

operation with various gases possible

experiments in vacuum or at a slight positive gauge pressure

electrically heated metal cylinder in the pressure vessel as experimental vessel

temperature-controlled heating element

vacuum generation with rotary vane pump

instrumentation: 1 temperature sensor on the metal cylinder, 1 power sensor at the heating element, 1 Pirani pressure sensor, 1 piezo-resistive pressure sensor

digital displays for temperature, pressure and heating power

 software for data acquisition via USB under Windows 10

Technical data

Heating element

output: 20W

radiation surface area: approx. 61cm2

Pressure vessel

pressure: -1…1,5bar

volume: 11L

Pump for vacuum generation

power consumption: 370W

nominal suction capacity: 5m3/h

final pressure with gas ballast: 2*10-3mbar

final pressure without gas ballast: 7*10-2mbar

Measuring ranges

negative pressure: 0,5*10-3…1000mbar

pressure: -1…1,5bar rel.

temperature: 0…250°C

power: 0…23W

 

We will contact you within 1 working day, please pay attention to the email.