RADIATION ERRORS in TEMPERATURE MEASUREMENT MODULE Didactic Equipment Thermal Transfer Training Equipment
H112F RADIATION ERRORS in TEMPERATURE MEASUREMENT MODULE Didactic Equipment Thermal Transfer Training Equipment for college, vocational training center, university.
- Description
- Inquiry
H112F RADIATION ERRORS in TEMPERATURE MEASUREMENT MODULE Didactic Equipment Thermal Transfer Training Equipment
A small scale bench top accessory designed to experimentally investigate how measured temperatures can be influenced by the effects of radiation, temperature sensor design and surface finish.
Three temperature sensors of different form and surface finish are mounted centrally in a circular stainless steel duct that is surrounded locally by an electrical heater. An additional temperature sensor records the temperature of the inside of the heated duct adjacent to the centrally mounted thermocouples. A radiation shield may be raised or lowered over the centrally mounted thermocouples to investigate the effects of shielding.
The circular duct is mounted on the discharge from a centrifugal fan. Air from the fan is blown through the duct past the temperature sensors at a controlled velocity of between 0 and 8m / s. The air velocity is measured by an in duct anemometer. The heater power supply and temperature sensors connect to the Heat Transfer Service Unit H112 while velocity is recorded on auxiliary instrumentation supplied as part of the H112F unit.
Related Products
Trainer Tubular Heat Exchanger Thermal Lab Equipment Educational Equipment
SR-WL302 Trainer Tubular Heat Exchanger Educational Equipment. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Thermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
ZF1116A Thermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
Brand: Shouldshine
Model:ZF1116A
Specification
Training panel for investigating the thermal expansion of different pipe sections
• Length of each pipe section 1200mm
• Pipe sections can be selected by ball valves
• Water connections made using quick action hose couplings
• Operation with hot and cold water supplies
• Adjustment of the water temperature using mixing battery with thermocouple
• Temperature measurement using battery-operated digital thermometer
• Force measuring device to determine the expansion force
• Pipe section length: 1000mm
• Nominal diameters: – PVC, PE, Cu: DN15 – Cu: DN8 – Steel: 1/2″
• Mixing battery connection: 1/2″
• Force measuring device: – spring rate per spring: 78N/mm – total spring rate c: 156N/mmThermal Expansion Training Panel Educational Equipment Vocational Training Equipment
SR3002 Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
Brand: ShouldShine
Model:SR3002
Learning Objectives / Experiments
– thermal expansion of different materials such as PVC, PE, copper and steel
– determination of thermal expansion coefficients and the expansion force
– measurement of pipe elongation
– effect of varying pipe diameter
– expansion compensator
Specification
[1] investigating the thermal expansion of different pipe sections
[2] pipe sections can be selected by ball valves
[3] water connections made using quick-release couplings
[4] operation with hot and cold water supplies
[5] adjustment of the water temperature using mixing battery with thermocouple
[6] temperature measurement using battery-operated digital thermometer
[7] force measuring device to determine the expansion force
Technical Data
Pipe section length: 1000mm
Nominal diameters- PVC, PE, Cu: – Cu: – Steel: 1/2″
Mixing battery connection: 1/2″
Force measuring device
– spring rate per spring: 78N/mm
– total spring rate c: 156N/mm
Measuring range
– temperature: -50…90°C
Dimensions and Weight
LxWxH: 1650x700x1850mm
Weight: approx. 100kg
Required for Operation
Cold and hot water connectionExpansion vessel training panel Vocational Training Equipment
SR3007 Expansion vessel training panel Vocational Training Equipment Teaching Equipment for college, university.
Radiator Training Panel Vocational Training Equipment Thermal Trainer
ZA1118A Radiator Training Panel Vocational Training Equipment Thermal Trainer
Description
The panel contains a pipe system with four radiators. Each radiator has an air bleed, a thermostatic valve and lockshield valve.
Rotameters indicate the flow rate through each individual radiator and for the entire system. Connections for cooling water make it possible to dissipate the heat supplied by the hot water. All water connections are made using quick-release couplings.
Training panel on heating systems and plumbing
•4 radiators with thermostatic valve, air bleed and adjustable lock shield valve
• 5 Rota meters
• 2 water connections for boiler DN15
• 2 cooling water connections DN15
• Water connections made using quick action hose couplings
• Hot and cold water supply
•Rota meters: 1x 1000ltr/h 4x 300ltr/h
• Radiator: plate heat exchanger with 10 plates, capacity: 3kW
Brand: Shouldshine
Model:ZF1118ACentral Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BFour way mixing valve training panel Educational Equipment Teaching Equipment
SR3006 Four way mixing valve training panel Educational Equipment Teaching Equipment for college, university.
Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainRadiator training panel heat transfer trainer thermal lab equipment
SR3008 Radiator training panel heat transfer trainer thermal lab equipment for college, university, vocational schools.
Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
SR2022 Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
Brand: ShouldShine
Model: SR2022
Learning Objectives / Experiments
– Variables affecting energy efficiency
* controller parameters
* refrigerant supercooling
– Interconnected operation of compressors
– Operation of a multicompressor controller
– Methods for returning oil in a multicompressor refrigeration system
– Representation of the thermodynamic cycle in the log p-h diagramSpecification
[1] Refrigeration system in multicompressor operation to investigate energy efficiency
[2] Refrigeration circuit with 3 compressors connected in parallel, condenser, thermostatic expansion valve and coaxial coil heat exchanger as evaporator
[3] Heat exchanger for refrigerant supercooling can be added via valves
[4] Glycol-water circuit includes pump and tank with heater serving as cooling load at the evaporator
[5] Multicompressor controller for the parallel operation of the compressors
[6] Separation of oil from the refrigerant on the delivery side and return to the intake side of the compressors
[7] Fan at the condenser with adjustable speed
[8] LabVIEW software for data acquisition via USB under Windows XP or Windows Vista
[9] Refrigerant R134a, CFC-free
Technical Data
3 compressors
– refrigeration capacity: each 1584W at -10°C/55°C
– power consumption: each 1156W at -10°C/55°C
Condenser with fan
– capacity: 4100W
– air flow: 1250m³/h
Coaxial coil heat exchanger capacity
– 4kW at ΔT=9K; 0,6m³/h glycol-water mixture
Glycol-water mixture pump
– max. flow rate: 5m³/h
– max. head: 6m
Heater power: 3kW
Tank
– glycol-water mixture: 23L
– refrigeration circuit receiver: 5,8L
Measuring ranges
– temperature: 4x 0…100°C, 4x -100°C…100°C
– pressure: 1x -1…9bar, 1x -1…24bar
– flow rate: 1x 1..25L/min
– compressor power: 0…4995W
Dimensions and Weight
l x w x h: 1800x700x1900mm
Weight: approx. 300kg
Connections
400V, 50/60Hz, 3 phases