Marcet Boiler Didactic Equipment Thermal Experiment Equipment
ZT0013 Marcet Boiler Didactic Equipment Thermal Experiment Equipment for college, vocational training center, university.
- Description
- Inquiry
ZT0013 Marcet Boiler Didactic Equipment Thermal Experiment Equipment
I.Product content
1.Product Overview
1.1 Overview
In a closed system filled with liquid, the liquid will reach a thermodynamic equilibrium during the vaporization process, and the position of the critical point mainly depends on the properties of the liquid and the temperature in the container. ZT0013 Marcet Boiler Test Bench is a training teaching device used in the laboratory to test the relationship between pressure and temperature in the heating process of steam boilers. Determine the position of the critical point by recording the steam pressure and temperature during the experiment. The temperature controller and pressure limiting valve are used as safety devices to protect the entire system at a safe temperature and pressure. The pressure and temperature in the process are set in the loop.
1.2 Features
①The pressure limiting valve and thermostat are arranged in the ZT0013 test bench circuit to ensure that the system is always at a safe pressure and temperature;
②The transient data during the change of the workbench is directly displayed on the display in digital form;
③It can quantitatively reflect the relationship between pressure and temperature in the process of water vaporization in a constant volume environment;
④The various physical data of the workbench change process can also be transferred to the PC through the USB interface for further processing.
Related Products
losses in a pipe system Vocational Training Equipment Educational Equipment
SR3005 losses in a pipe system Vocational Training Equipment Educational Equipment
Brand: ShouldShine
Model:SR3005
Learning Objectives / Experiments
– pressure curve in a closed pipe system with circulation pump
– influence of pipe diameter, flow velocity, change in
cross-section and pipe fittings on the pressure losses
– determination of pump characteristics, system characteristics and the operating point
Specification
[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] closed water circuit with pump and tank
[5] integrated bleed valve on manometer and in the pipe section
[6] flow measurement using rotameter
[7] measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Technical Data
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 140kg
Required for Operation
230V, 50Hz, 1 phaseExpansion vessel training panel Vocational Training Equipment
SR3007 Expansion vessel training panel Vocational Training Equipment Teaching Equipment for college, university.
Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
SR3002 Thermal Expansion Training Panel Educational Equipment Vocational Training Equipment
Brand: ShouldShine
Model:SR3002
Learning Objectives / Experiments
– thermal expansion of different materials such as PVC, PE, copper and steel
– determination of thermal expansion coefficients and the expansion force
– measurement of pipe elongation
– effect of varying pipe diameter
– expansion compensator
Specification
[1] investigating the thermal expansion of different pipe sections
[2] pipe sections can be selected by ball valves
[3] water connections made using quick-release couplings
[4] operation with hot and cold water supplies
[5] adjustment of the water temperature using mixing battery with thermocouple
[6] temperature measurement using battery-operated digital thermometer
[7] force measuring device to determine the expansion force
Technical Data
Pipe section length: 1000mm
Nominal diameters- PVC, PE, Cu: – Cu: – Steel: 1/2″
Mixing battery connection: 1/2″
Force measuring device
– spring rate per spring: 78N/mm
– total spring rate c: 156N/mm
Measuring range
– temperature: -50…90°C
Dimensions and Weight
LxWxH: 1650x700x1850mm
Weight: approx. 100kg
Required for Operation
Cold and hot water connectionHeat Transfer Bench Educational Equipment Thermal Training Equipment
SR1162E Heat Transfer Trainer Heat Transfer Bench Educational Equipment Thermal Training Equipment
1 Product Overview
1.1 Profile
This product is an extensible educational experiment equipment for students to observe the heating, cooling and air movement of the device during operation. Students can observe the mixing of air and conduct tests to monitor temperature and air pressure. Grasp its control principle and control method, cultivate students’ corresponding knowledge and skills, suitable for higher vocational schools, engineering university, secondary vocational school and technical school related professional teaching and skills training evaluation.
1.2 Feature
(1) The training platform adopts an aluminum column frame structure with a universal wheel at the bottom for flexible movement. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful. The instrument and power supply are integrated and installed, which is easy to use and not easily damaged.
(2) The training platform has a good safety protection system.
2 Technical specifications
(1) Input Power: AC220V±10% 60Hz
(2) Fan: Supply voltage: AC220V/50Hz Power: 1.5kW; Maximum flow rate: 2.160m3/h
(3) Overall dimensions: 2000mm x 750mm x 2100mm
(4) Overall capacity: <2.5KVA
(5) Weight: <100kg
(6) Working conditions: Ambient temperature -10°C to +40°C Relative humidity <85% (25°C)
3 Product introduction
3.1 Power control panel
(1)The power control panel adopts an aluminum alloy frame and a closed box structure, which is integrated with the placement rack below.
(2)Configured with circuit breaker, power indicator, temperature adjustment knob, thermometer, power socket, differential pressure gauge, thermostat and intelligent electrical parameter measuring instrument
(3)The power input is controlled by the leakage breaker and the emergency stop control button is provided. In case of emergency, you press emergency stop button is so as to cut off the power.
3.2 Training workbench
(1)Training workbench:
The training table is supported by aluminum pillars, and the bottom universal wheel has a brake that can be moved and positioned flexibly. The desktop uses a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-pressure fire-resistant panels. The structure is firm and beautiful.
(2) Heat exchange systemInstallation technology losses in different pipes Vocational Training Equipment Didactic Equipment
SR3003 Installation technology losses in different pipes Vocational Training Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3003
investigation of the pressure losses of flow through pipes
– measurement of the pressure differential on different pipe sections
– influence of various pipe diameters
– influence of different materials and surface roughness
– effect of the flow velocity
– comparison between experiment and theory
Specification
[1] investigation of friction-induced pressure losses in flow through pipes
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] four measuring sections with different pipe crosssections and materials
[5] pipe sections can be selected via ball valves
[6] water connections made using quick-release couplings in the inflow and return
[7] flow can be adjusted via valves
[8] flow measurement using rotameter
[9] differential pressure measurement via differential pressure meter with display
Technical Data
Pipe sections measuring length: 1000mm
– pipe section 1: transparent plastic, diameter: 20×1,5mm
– pipe section 2: steel, diameter: 1/2″
– pipe section 3: copper, diameter: 18x1mm
– pipe section 4: copper, diameter: 15x1mm
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mm Weight: approx. 92kg
Required for Operation
Water connection: 1500L/h, drainZM6152 Heat Exchangers in the Refrigeration Circuit Technical Teaching Equipment
Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment,air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
Central Geo Thermal Heating System Thermal Experiment Equipment
ZF1122B Central Geo Thermal Heating System Thermal Experiment Equipment
“Specification
Function and operating behaviors of a modern heating system with digital heating controller
• Four-way mixer and three-way mixer
• Electric boiler
• 2 circulating pumps, 1 domestic water pump
• 4 different radiators and additional plate heat exchanger with shower system as domestic water consumer
• Colored pipes indicate heating feed and return
• Measurement of temperature, pressure and flow rate
• Boiler, 4 stages: 6/9/12/15kW,
• Max. Feed temperature: 95°C,
• Water tank capacity: 16 ltr
• Circulating pump 3 stages: 60W,
• Max. Flow rate: 60ltr/min,
• Max. Head: 4m
• Domestic water pump: 20W, max. 640ltr/h, max. 0.14bar
• Plate heat exchanger: 3kW, 10 plates
• Measuring ranges: temperature: 3x 20…120°C / 2x 0…120°C / 2x 0…100°C / 4x 0…80°C, pressure: 8x 0…2.5bar, flow rate: 100…1000ltr/h, water meter: 2.5m³/h
“• Manual with theory and experiments
• Size(LxWxH): 1500x900x1700mm
• Weight: 300Kg
a. Heat pump system
b. Compressor : 1HP
c. Condenser : Air-cooled type
d. Evaporator: pin, Tube air-cooled type
e. Evaporator
f. Expansion Valve : manual type
g. Liquid receiver : 1/2HP
h. Accumulator : 1HP
i. Electronic valve : 3/8” nut clamp type
j. Manometer
k. Fitting nipple
l. Sight Glass
m. Electric control module: DC24V
n. Thermostat range: -50℃‾100℃
o. Geothermal system
-Ground unit chamber
-Water unit chamber
Brand: Shouldshine
Model:ZF1122BEnergy Efficiency in Refrigeration Systems Refrigerator Training Equipment
SR2022 Energy Efficiency in Refrigeration Systems Refrigerator Training Equipment
Brand: ShouldShine
Model: SR2022
Learning Objectives / Experiments
– Variables affecting energy efficiency
* controller parameters
* refrigerant supercooling
– Interconnected operation of compressors
– Operation of a multicompressor controller
– Methods for returning oil in a multicompressor refrigeration system
– Representation of the thermodynamic cycle in the log p-h diagramSpecification
[1] Refrigeration system in multicompressor operation to investigate energy efficiency
[2] Refrigeration circuit with 3 compressors connected in parallel, condenser, thermostatic expansion valve and coaxial coil heat exchanger as evaporator
[3] Heat exchanger for refrigerant supercooling can be added via valves
[4] Glycol-water circuit includes pump and tank with heater serving as cooling load at the evaporator
[5] Multicompressor controller for the parallel operation of the compressors
[6] Separation of oil from the refrigerant on the delivery side and return to the intake side of the compressors
[7] Fan at the condenser with adjustable speed
[8] LabVIEW software for data acquisition via USB under Windows XP or Windows Vista
[9] Refrigerant R134a, CFC-free
Technical Data
3 compressors
– refrigeration capacity: each 1584W at -10°C/55°C
– power consumption: each 1156W at -10°C/55°C
Condenser with fan
– capacity: 4100W
– air flow: 1250m³/h
Coaxial coil heat exchanger capacity
– 4kW at ΔT=9K; 0,6m³/h glycol-water mixture
Glycol-water mixture pump
– max. flow rate: 5m³/h
– max. head: 6m
Heater power: 3kW
Tank
– glycol-water mixture: 23L
– refrigeration circuit receiver: 5,8L
Measuring ranges
– temperature: 4x 0…100°C, 4x -100°C…100°C
– pressure: 1x -1…9bar, 1x -1…24bar
– flow rate: 1x 1..25L/min
– compressor power: 0…4995W
Dimensions and Weight
l x w x h: 1800x700x1900mm
Weight: approx. 300kg
Connections
400V, 50/60Hz, 3 phasesInstallation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
SR3004 Installation technology losses in pipe bends Technical Teaching Equipment Didactic Equipment
Brand: ShouldShine
Model:SR3004
Learning Objectives / Experiments
– flow measurement
– differential pressure measurement
– effect of flow and surface roughness
– effect of the flow velocity
– effect of changes in pipe direction
Specification
[1] investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] simply selection of the measuring sections via hose connection with quick-release couplings
[5] flow can be adjusted via valves
[6] flow measurement using rotameter
[7] differential pressure measurement via differential pressure meter with display
Technical Data
Measuring sections: 2300mm
– pipe section 1: steel, diameter: 1/2″, 90° pipe angle
– pipe section 2: steel, diameter: 1/2″, 90° pipe bend
– pipe section 3: copper, diameter: 18x1mm,90° pipe angle
– pipe section 4: copper, diameter: 18x1mm,90° pipe bend
Differential pressure meter
Measuring ranges- flow rate: 150…1600L/h- differential pressure: -350mbar…350mbar
Dimensions and Weight LxWxH: 1650x700x1850mmWeight: approx. 100kg
Required for Operation
Water connection: 1500L/h, drainThermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
ZF1116A Thermal Expansion Trainer Panel Vocational Training Equipment Teaching Equipment
Brand: Shouldshine
Model:ZF1116A
Specification
Training panel for investigating the thermal expansion of different pipe sections
• Length of each pipe section 1200mm
• Pipe sections can be selected by ball valves
• Water connections made using quick action hose couplings
• Operation with hot and cold water supplies
• Adjustment of the water temperature using mixing battery with thermocouple
• Temperature measurement using battery-operated digital thermometer
• Force measuring device to determine the expansion force
• Pipe section length: 1000mm
• Nominal diameters: – PVC, PE, Cu: DN15 – Cu: DN8 – Steel: 1/2″
• Mixing battery connection: 1/2″
• Force measuring device: – spring rate per spring: 78N/mm – total spring rate c: 156N/mm